Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Do not need to remove the installation of flange and combustion cylinder, it can be directly removed burner.
Manual flow adjustment.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Momophase electric motor to run fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating Ip40.
Plastic protection cover.
Air inlet with quieter.
Baite Gas Burner BTN5/8/12G/GW
Gas-fired burner.
Single stage operation (on/off).
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Do not need to remove the installation of flange and combustion cylinder, it can be directly removed burner.
Manual flow adjustment.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Monophase electric motor to run fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Plastic protection cover.
Air inlet with quieter.
Baite Gas Burner BTN15-20-30G-GC
Gas-fired burner.
One-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Do not need to remove the installation of flange and combustion cylinder, it can be directly removed burner.
The air flow is adjusted by man in one-stage fire burner.
The sliding/modulation type has servo motor with cam, it can control air and fuel supply at the same time. When the burner pauses, close the air damper to reduce heating loss.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Monophase electric motor to run fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Plastic protection cover.
Air inlet with quieter.
Baite Gas Burner BTN40/55G/G C
Gas-fired burner.
Two-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Hinged connection, automatic open control, maintenance is convenient.
Minimum and maximum air flow regulation for the first and second stage by means of an electric servomotor with pause closure of the gate to prevent any heat dispersion to the flue.
The servo motor, which is fixed with a cam, can adjust the consumption for fuel and air.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Three-phase electric motor to run the fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Baite Gas Burner BTN85/120/150G C
Gas-fired burner.
Two-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Hinged connection, automatic open control, maintenance is convenient.
Minimum and maximum air flow regulation for the first and second stage by means of an electric servomotor with pause closure of the gate to prevent any heat dispersion to the flue.
The servo motor, which is fixed with a cam, can adjust the consumption for fuel and air.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Three-phase electric motor to run the fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Baite Gas Burner BTN210/250GC
Gas-fired burner.
Two-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Hinged connection, automatic open control, maintenance is convenient.
Minimum and maximum air flow regulation for the first and second stage by means of an electric servomotor with pause closure of the gate to prevent any heat dispersion to the flue.
The servo motor, which is fixed with a cam, can adjust the consumption for fuel and air.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Three-phase electric motor to run the fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Baite Gas Burner BTN400/600GC/ GE
Gas-fired burner.
Two-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Hinged connection, automatic open control, maintenance is convenient.
Minimum and maximum air flow regulation for the first and second stage by means of an electric servomotor with pause closure of the gate to prevent any heat dispersion to the flue.
The servo motor, which is fixed with a cam, can adjust the consumption for fuel and air.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Three-phase electric motor to run the fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Baite Gas Burner BTN800/1000GC/ GE
Gas-fired burner.
Two-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Hinged connection, automatic open control, maintenance is convenient.
Minimum and maximum air flow regulation for the first and second stage by means of an electric servomotor with pause closure of the gate to prevent any heat dispersion to the flue.
The servo motor, which is fixed with a cam, can adjust the consumption for fuel and air.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.
Three-phase electric motor to run the fan.
Flame presence check by ionisation electrode.
Electrical plant protection rating IP40.
Baite Gas Burner BTN1200/1500GC/GE
Gas-fired burner.
Two-stage sliding/modulating working.
Air-gas mixing at blast-pipe.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Hinged connection, automatic open control, maintenance is convenient.
Minimum and maximum air flow regulation for the first and second stage by means of an electric servomotor with pause closure of the gate to prevent any heat dispersion to the flue.
The servo motor, which is fixed with a cam, can adjust the consumption for fuel and air.
Using a flange and high temperature resistant heat insulation pads connected to the boiler.
Combustion air intake with air flow adjustment device.