Baite Light Oil Burner BT-K10KL

  • Light oil burner.
  • Single stage operation (on/off).
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • Manual flow adjustment.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Adjustable blast-pipe with stainless steel nozzle and deflector disk in steel.
  • Monophase electric motor to run fan and pump.
  • Flame presence check by photoresistance.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT-M8SLF/M12SL

  • Light oil burner.
  • Single stage operation (on/off).
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • Manual flow adjustment.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Adjustable blast-pipe with stainless steel nozzle and deflector disk in steel.
  • Monophase electric motor to run fan and pump.
  • Flame presence check by photoresistance.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT14L/LR

  • Light oil burner.
  • Single/Two stage operation (on/off).
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
  • Two stage air flow regulation for first and second stage by means of hydraulic regulator.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Monophase electric motor to run fan and pump.
  • Flame presence check by photoresistance.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT18/26/35L/LR

  • Light oil burner.
  • Single/Two stage operation (on/off).
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
  • Single stage flow adjustment.
  • Two stage air flow regulation for first and second stage by means of hydraulic regulator.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Monophase electric motor to run fan and pump.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT40/55L/LR

  • Light oil burner.
  • Single/Two stage operation (on/off).
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
  • Single stage flow adjustment.
  • Two stage air flow regulation for first and second stage by means of hydraulic regulator.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Monophase electric motor to run fan and pump.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT75/100 LR

  • Light oil burner.
  • Two stage operation (on/off).
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
  • Single stage flow adjustment.
  • Two stage air flow regulation for first and second stage by means of hydraulic regulator.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Monophase electric motor to run fan and pump.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT120/180/250LR/LC

  • Light oil burner.
  • Two-stage sliding/modulating working.
  • High pressure mechanical atomisation of fuel using nozzle.
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
  • The hinge connection, can be opened naturally.
  • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
  • Two-stage Air flow regulation for first and second stage by means of hydraulic regulator. The burner is paused, close the throttle to reduce the loss of furnace heat.
  • Sliding/modulating The servo motor which fixed with a cam can adjust the consumption for fuel and air.
  • One flange and one insulating seal for boiler fastening.
  • Combustion air intake with air flow adjustment device.
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
  • Three-phase electric motor to run fan and pump.
  • Flame presence check by photoresistance.
  • Electrical plant protection rating Ip40.

Baite Light Oil Burner BT300/350/600LR/LC

  • Light oil burner
  • Two-stage sliding/modulating working
  • High pressure mechanical atomisation of fuel using nozzle
  • Ability to obtain optimal combustion values by regulating combustion air and blast-pipe
  • The hinge connection, can be opened naturally
  • Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler
  • Two-stage Air flow regulation for first and second stage by means of hydraulic regulator. The burner is paused, close the throttle to reduce the loss of furnace heat
  • Sliding/modulating The servo motor which fixed with a cam can adjust the consumption for fuel and air
  • One flange and one insulating seal for boiler fastening
  • Combustion air intake with air flow adjustment device
  • Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers
  • Three-phase electric motor to run fan and pump
  • Flame presence check by photoresistance
  • Electrical plant protection rating Ip40