High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Manual flow adjustment.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Adjustable blast-pipe with stainless steel nozzle and deflector disk in steel.
Monophase electric motor to run fan and pump.
Flame presence check by photoresistance.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT-M8SLF/M12SL
Light oil burner.
Single stage operation (on/off).
High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Manual flow adjustment.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Adjustable blast-pipe with stainless steel nozzle and deflector disk in steel.
Monophase electric motor to run fan and pump.
Flame presence check by photoresistance.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT14L/LR
Light oil burner.
Single/Two stage operation (on/off).
High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
Two stage air flow regulation for first and second stage by means of hydraulic regulator.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Monophase electric motor to run fan and pump.
Flame presence check by photoresistance.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT18/26/35L/LR
Light oil burner.
Single/Two stage operation (on/off).
High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
Single stage flow adjustment.
Two stage air flow regulation for first and second stage by means of hydraulic regulator.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Monophase electric motor to run fan and pump.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT40/55L/LR
Light oil burner.
Single/Two stage operation (on/off).
High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
Single stage flow adjustment.
Two stage air flow regulation for first and second stage by means of hydraulic regulator.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Monophase electric motor to run fan and pump.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT75/100 LR
Light oil burner.
Two stage operation (on/off).
High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
Single stage flow adjustment.
Two stage air flow regulation for first and second stage by means of hydraulic regulator.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Monophase electric motor to run fan and pump.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT120/180/250LR/LC
Light oil burner.
Two-stage sliding/modulating working.
High pressure mechanical atomisation of fuel using nozzle.
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
The hinge connection, can be opened naturally.
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
Two-stage Air flow regulation for first and second stage by means of hydraulic regulator. The burner is paused, close the throttle to reduce the loss of furnace heat.
Sliding/modulating The servo motor which fixed with a cam can adjust the consumption for fuel and air.
One flange and one insulating seal for boiler fastening.
Combustion air intake with air flow adjustment device.
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
Three-phase electric motor to run fan and pump.
Flame presence check by photoresistance.
Electrical plant protection rating Ip40.
Baite Light Oil Burner BT300/350/600LR/LC
Light oil burner
Two-stage sliding/modulating working
High pressure mechanical atomisation of fuel using nozzle
Ability to obtain optimal combustion values by regulating combustion air and blast-pipe
The hinge connection, can be opened naturally
Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler
Two-stage Air flow regulation for first and second stage by means of hydraulic regulator. The burner is paused, close the throttle to reduce the loss of furnace heat
Sliding/modulating The servo motor which fixed with a cam can adjust the consumption for fuel and air
One flange and one insulating seal for boiler fastening
Combustion air intake with air flow adjustment device
Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers